160
likes
16
comments
daily view 0
monthly view 0

Share

Live Analytics

Comments 0

Using the Elcometer 456 Zero Offset Calibration in accordance with ISO 19840 on Ferrous Substrates Analytics Table

Income Estimates for Using the Elcometer 456 Zero Offset Calibration in accordance with ISO 19840 on Ferrous Substrates

Based on this YouTube video's total view count of 34.8K views and industry-standard rates, the estimated total earning is $24 - $70 through ad revenue. Historical data is not yet available to calculate daily, weekly, or monthly averages.

About Using the Elcometer 456 Zero Offset Calibration in accordance with ISO 19840 on Ferrous Substrates

Explore Using the Elcometer 456 Zero Offset Calibration in accordance with ISO 19840 on Ferrous Substrates with 34,889 views, 160 likes, and 16 comments. Experience the impact of this video content that has captured audience attention.

How to calibrate the Elcometer 456 Coating Thickness Gauge in accordance with ISO 19840, for rough surfaces (or blast coated substrates), on ferrous substrates. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gauge’s ±1% accuracy by calibrating the coating thickness instrument to suit the application. The Elcometer 456 Dry Film Thickness Gauge can measure the thickness of a coating on smooth, and on rough or blast coated substrates; and there are a number of calibration methods for each substrate profile. When measuring on rough surfaces, if you have access to a sample of the uncoated substrate you will be measuring, then you should undertake a rough surface (or 2-point) calibration. However, if you don’t have access to the uncoated substrate, then you can use the Elcometer 456’s patented Zero Offset calibration method, which helps measure film thicknesses in accordance with ISO 19840. ISO 19840 simply states that if a blast profile is unknown, you should calibrate on smooth steel and then subtract a predefined correction value from the measurement taken on the coated surface. The Elcometer 456’s patented zero offset calibration automatically subtracts this correction value from the measurement, so you don’t have to. The Elcometer 456 is an intelligent gauge, so, once the gauge has been set to the Zero Offset Calibration, it will guide you through the calibration process, one step at a time. For more information on the Elcometer 456 Coating Thickness Gauge, please contact Elcometer at [email protected] or visit our website: http://www.elcometer.com/en/coating-inspection/dry-film-thickness/dry-film-thickness-digital/elcometer-456-coating-thickness-gauge.html ----- Click here to download the video script in English: https://www.elcometer.com/pub/media/PDF/Video_Scripts/Elcometer_456_Zero_Offset_Calibration_ISO_19840.pdf ----- STANDARDS: AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

About YouTube Real-Time View Count

With SocialCounts.org’s view counter, track your YouTube video’s live view count and YouTube likes count in real time with fast, reliable updates.

Watch every YouTube video live view count rise with our real-time YouTube views tracker—built for accuracy and minimal delay.

Follow YouTube real time views as they happen, using our dedicated view counter for YouTube videos.

Get up-to-date live view count on YouTube and see real-time growth with SocialCounts.org’s smart tracking tools.

Embed Widget

Parameters:

  • fullscreen=true - Fullscreen counter
  • graph=true - Live graph chart
  • counter=0/1/2 - Select counter (0=likes, 1=views, 2=comments)
URL

Click to copy the embed URL to your clipboard